An end-to-end test of a CLI starts where a user does, with a command line, and checks what the user gets back, namely output, error messages, and an exit status. Go programs usually test end to end by building the binary and running it as a separate process. CONGA also lets a test run the whole app inside the test process, with no binary. Each sees things the other misses, and both sit beside unit tests of the functions a command calls.

A test can build the program and run it as a separate process, with os/exec or a script runner such as testscript. The process gets a real command line, real environment variables, a real working directory, and real standard streams, and it ends with a real exit status. The test sees exactly what a user sees.

CONGA’s own example programs are tested this way. Each one has scripts under _examples/NN-*/testdata/ with lines such as exit-status 2 subcommands-basic, which runs the program and checks that it exits with status 2.

The cost is speed, and the distance between a failure and its cause. Each case starts a process, the scripts sit outside Go, and a failure points at output rather than at a line of code. In return, these tests see the exit status the process really returns, and everything the program writes to its standard output and standard error, whichever code writes it.

A test can instead build the same App that main builds, give it a command line with Args and streams with Stdin, Stdout, and Stderr, and call RunContext. CONGA parses the command line, reads the environment and config file, and runs the commands, all inside the test process. The test gets back the error RunContext returns, and whatever the commands wrote to the streams. There is no binary to build, and a failure is an ordinary Go test failure.

The streams a test sets belong to that App, and reach a command only through session.Stdout(), session.Stderr(), and session.Stdin(). In a normal run they are the process’s own streams, so a command that writes through the session behaves the same for a user as one that calls fmt.Println. In a test they are whatever the test passed, so the same code writes into a buffer.

The arrangement breaks as soon as a command, or a package it calls, writes to os.Stdout or reads os.Stdin directly, as fmt.Println does. The command still works at the terminal, and the test never sees that output or supplies that input. A package that accepts an io.Reader or io.Writer can be handed the session’s streams, while one that only uses the process’s streams leaves those lines to the process-level tests. CONGA’s own output (help, version, and the error messages Exit prints) already goes to the app’s streams.

An in-process run returns an error, not an exit status. The status a user would see comes from app.Exit, which maps the error to 0, 1, or 2 and calls os.Exit. A test can call Exit too, after giving ExitFunc a function that records the status in place of exiting, to check the status and the message on standard error. How to test a command shows it. A command that calls os.Exit itself ends the test binary.

The run also shares the test’s process. The environment and the working directory belong to the whole process, so a test isolates itself with t.Setenv and t.Chdir, and such tests can’t run in parallel. Tests that set neither can call t.Parallel(), because the command line and streams belong to each App.

An App runs once. A second Run or RunContext on the same App panics with conga: App already executed, so each test builds its own, usually through a function that main shares, as newApp does in Test a CLI.

Unit tests call ordinary Go functions with ordinary values, as in any Go program. They don’t involve CONGA at all, they are the fastest tests a program has, and they are the right place for the logic a command runs, such as building a deployment plan, formatting a report, or deciding whether a value is valid.

A command struct itself is a poor target for this. Its fields are containers such as conga.OptionalFlag[int], and only CONGA fills them, while it binds the command line, environment, and config files. The containers have no exported setters. A test can’t build a DeployCmd with --replicas 3 and call its Run method. Keeping Run short, so that it reads the containers and hands plain values to functions that do the work, leaves most of a program testable this way.

What unit tests can’t see is the command line, which is what the end-to-end tests are for. That covers flag names, defaults, required flags, the config file, the environment, and the messages a user gets when they get something wrong.

Most programs need more than one. Put the logic in functions and test it there, where tests are cheapest. Use in-process runs for the command line itself, checking that a flag exists and has the right default, that the config file and environment reach the right flags, that a prompt reads its answer, and that a mistake is a usage error. Keep a few process-level tests for what only a real process shows, which is the status the binary returns, including from a command that calls os.Exit itself, and output that doesn’t go through the session.

How much an in-process run checks depends on the commands. If every command reads and writes through the session, it checks nearly everything a user sees, at the speed of a unit test. If some commands print directly, those lines are visible only to the process-level tests.